Vonberg safety valves and flow limiters

More from Vonberg
Contact Us

Vonberg 21850 Slip-in Cartridge Inline Flow Limiter Valve

In-line flow limiter (slip-in cartridge) prevents free fall if there is a line failure while allowing a metered flow after closing. A flow below the specified limit is allowed from port 1 to port 2 while a flow above the limit is treated as a line failure and the flow is limited to a bleed rate after closing of 2.0 - 3.0 gpm at 3500 PSI. Flow from port 2 to port 1 passes through the controlling orifice but is uncontrolled.
​​Models:
  • 21850-006
  • 21850-008
  • 21850-010
  • 21850-012
  • 21850-014
  • 21850-016
  • 21850-024
​​Call us for a quote or more information. 
317-849-5115 / 800-875-5196
Quick Quote
Picture
  • Steel components
  • Non-standard bleed flow rates are available
  • Operating pressure: 3500 PSI
  • Temperature range: 250° f to -40° f
  • Reopening differential: 50 PSI
  • Closing flow tolerance: +15% / -0%

Vonberg 28050-100 Inline Flow Limiter Valve with Female NPTF Ports

A female NPTF port in-line velocity fuse with full-line shut-off if a line fails. Flow below the specified limit is permitted from port 1 to port 2. When flow exceeds the limit it is treated as a line failure and is reduced to 2.0 - 3.0 gpm at 3000 PSI. Flow from port 2 to port 1 passes through the controlling orifice but is uncontrolled.​
​Models:

  • 28050-102
  • 28050-103
  • 28050-104
  • 28050-106

​ ​​Call us for a quote or more information. 
317-849-5115 / 800-875-5196
Quick Quote
Picture
  • Steel components
  • Non-standard bleed flow rates are available
  • Operating pressure: 3500 PSI
  • Temperature range: 250° f to -40° f
  • Reopening differential: 50 PSI
  • Closing flow tolerance: +15% / -0%

Vonberg 28050-200 Inline Flow Limiter Valve with Female SAE Ports

In-line velocity fuse with female SAE ports. Full-line shut-off in the event of a line failure. A flow below the specified limit is allowed from port 1 to port 2. Flow above the limit is treated as a line failure and is limited to 2.0 - 3.0 gpm at 3000 PSI. Flow from port 2 to port 1 passes through the controlling orifice but is not a controlled flow.
​Models:
  • 28050-204
  • 28050-206
  • 28050-208
  • 28050-210
  • 28050-212

​ ​​Call us for a quote or more information. 
317-849-5115 / 800-875-5196
Quick Quote
Picture
  • Steel components
  • Non-standard bleed flow rates are available
  • Operating pressure: 3500 PSI
  • Temperature range: 250° f to -40° f
  • Reopening differential: 50 PSI
  • Closing flow tolerance: +15% / -0%

Vonberg 28050-500 Inline Flow Limiter Valve with Male NPTF Connections

In-line flow limiter with male NPTF connections that prevents free fall during and after a line failure, but allows a controlled flow after closing. A flow below the limit is allowed from port 1 to port 2. Flow above the specified limit is treated as a line failure and is limited to 2.0 - 3.0 gpm at 3500 PSI.
​
Models:
  • 28050-502
  • 28050-503
  • 28050-504
  • 28050-506
  • 28050-508
  • 28050-512

​ ​​Call us for a quote or more information. 
317-849-5115 / 800-875-5196
Quick Quote
Picture
  • Steel components
  • Non-standard bleed flow rates are available
  • Operating pressure: 3500 PSI
  • Temperature range: 250° f to -40° f
  • Reopening differential: 50 PSI
  • Closing flow tolerance: +15% / -0%

Vonberg 28051-200 Inline Flow Limiter Valve with Female SAE to Male JIC

This female SAE o-ring port inlet and a male JIC outlet in-line flow limiter avoids free fall in the event of a line failure, but allows a metered flow after closing. A flow below the limit is permitted from port 1 to port 2. Flow above the limit is treated as a line failure and restricted to 2.0 - 3.0 gpm at 3500 PSI.
​
Models:
  • 28051-204
  • 28051-206
  • 28051-208
  • 28051-210
  • 28051-212

​​​Call us for a quote or more information. 
317-849-5115 / 800-875-5196
Quick Quote
Picture
  • Steel components
  • Non-standard bleed flow rates are available
  • Operating pressure: 3500 PSI
  • Temperature range: 250° f to -40° f
  • Reopening differential: 50 PSI
  • Closing flow tolerance: +15% / -0%

Vonberg 28051-800 Inline Flow Limiter Valve Male SAE to Male JIC

In-line flow limiter with male JIC out port and male SAE o-ring inflow port. It prevents free fall during a line failure, and the provides a controlled flow of 2.0 - 3.0 gpm at 3500 PSI after closing.
​
Models:
  • 28051-804
  • 28051-806
  • 28051-808
  • 28051-810
  • 28051-812
  • 28051-816
  • 28051-824

​​Call us for a quote or more information. 
317-849-5115 / 800-875-5196
Quick Quote
Picture
  • Steel components
  • Fail safe design
  • Rapid response
  • Non-standard bleed flow rates are available upon request
  • Operating pressure: 3500 PSI
  • Temperature range: 250° f to -40° f
  • Reopening differential: 50 PSI
  • Closing flow tolerance: +15% / -0%

Vonberg 28059-500 Inline Flow Limiter Valve with Male NPTF to Male ORS

In-line velocity fuse. Male NPTF inlet and male ORS outlet. Full-line shut-off during a line failure. During normal operation, a below the limit flow is permitted from port 1 to port 2. A flow above the limit is treated as a line failure and is flow is restricted to 2.0 - 3.0 gpm at 3000 PSI.
​​Models:
  • 28059-502
  • 28059-503
  • 28059-504
  • 28059-506
  • 28059-508
  • 28059-512

​
​​Call us for a quote or more information. ​
317-849-5115 / 800-875-5196
Quick Quote
Picture
  • Steel components
  • Non-standard bleed flow rates are available
  • Operating pressure: 3500 PSI
  • Temperature range: 250° f to -40° f
  • Reopening differential: 50 PSI
  • Closing flow tolerance: +15% / -0%

Vonberg 28059-800 Inline Flow Limiter Valve with Male SAE to Male ORS

In-line velocity fuse. Male SAE inlet and male ORS outlet. Full-line shut-off during a line failure. Flow below the limit is permitted from port 1 to port 2 during normal operation. If the flow rises above the limit, it is treated as a line failure and is restricted to a maximum of 2.0 - 3.0 gpm at 3000 PSI.
Models:
  • 28059-806
  • 28059-808
  • 28059-810
  • 28059-812
  • 28059-816
  • 28059-824

​ ​Call us for a quote or more information. 
317-849-5115 / 800-875-5196
Quick Quote
Picture
  • Steel components
  • Non-standard bleed flow rates are available
  • Operating pressure: 5000 PSI
  • Temperature range: 250° f to -40° f
  • Reopening differential: 50 PSI
  • Closing flow tolerance: +15% / -0%

Vonberg 28950-500 Inline Flow Limiter Valve with Male NPTF to Female NPTF

In-line velocity fuse. Male NPTF inlet and female NPTF outlet. Offers full-line shut-off during a line failure. During normal function, a flow below the limit is permitted from port 1 to port 2. If flow rises above the limit it is treated as a line failure and is limited to 2.0 - 3.0 gpm at 3000 PSI.
​​Models:
  • 28950-502
  • 28950-503
  • 28950-504
  • 28950-506
  • 28950-508
​ ​Call us for a quote or more information. 
317-849-5115 / 800-875-5196
Quick Quote
Picture
  • Steel components
  • Non-standard bleed flow rates are available
  • Operating pressure: 3500 PSI
  • Temperature range: 250° f to -40° f
  • Reopening differential: 50 PSI
  • Closing flow tolerance: +15% / -0%

Vonberg 28951-100 Inline Flow Limiter Valve with Female NPTF to Male NPTF

In-line velocity fuse. Female NPTF inlet, male NPTF outlet. Full-line shut-off during a line failure. During normal operation, a flow below the limit is permitted from port 1 to port 2. If a line failure occurs, flow is limited to 2.0 - 3.0 gpm at 3000 PSI. Flow from port 2 to port 1 passes through the controlling orifice but is uncontrolled.
​​Models:
  • 28951-102
  • 28951-103
  • 28951-104
  • 28951-106

​Call us for a quote or more information. 
317-849-5115 / 800-875-5196
Quick Quote
Picture
  • Steel components
  • Non-standard bleed flow rates are available
  • Operating pressure: 3500 PSI
  • Temperature range: 250° f to -40° f
  • Reopening differential: 50 PSI
  • Closing flow tolerance: +15% / -0%

Vonberg 8200 Flow Limiter Valve, Cartridge-sytle with Standard Cavity

Cartridge flow limiter. Avoids free fall during a line failure, while allowing a controlled flow of 2.0 - 3.0 gpm at 3000 PSI after closing.
Models:
  • 8204
  • 8206
  • 8208
  • 8210
  • 8212
  • 8216
​

​
​​Call us for a quote or more information. 
317-849-5115 / 800-875-5196
Quick Quote
Picture
  • Steel components
  • Industry common cavity
  • Positive close
  • Non-standard bleed flow rates are available
  • Operating pressure: 3500 PSI
  • Temperature range: 250° f to -40° f
  • Reopening differential: 50 PSI
  • Closing flow tolerance: +15% / -0%

Vonberg 8400 90-degree Swivel Elbow Inline Flow Limiter Valve with Male SAE to Female NPTF Ports

In-line, 90 degree swivel elbow flow limiter. NPTF outlet port. Provides partial-line shut-off during a line failure. Allows restricted flow of 2.0 - 3.0 gpm at 3000 PSI after closing.
​Models:
  • 8402
  • 8403
  • 8404
  • 8406



​
Call us for a quote or more information. 
317-849-5115 / 800-875-5196
Quick Quote
Picture
  • Steel components
  • Positive close
  • Swivel design for easy alignment
  • 90° elbow for low profile applications
  • Non-standard bleed flow rates are available
  • Operating pressure: 3500 PSI
  • Temperature range: 250° f to -40° f
  • Reopening differential: 50 PSI
  • Closing flow tolerance: +15% / -0%

Vonberg 8600 Inline Flow Limiter Valve, Threaded, Insertable

In-line, threaded, insertable velocity fuse. Provides full-line shut-off during a line failure. In normal operation, flow below the limit is permitted from port 1 to port 2. Flow above the limit is treated as a line failure and limited to 2.0 - 3.0 gpm at 3000 PSI.
​Models:
  • 8604
  • 8606
  • 8608
  • 8610
  • 8612
  • 8616
  • 8620
  • 8624
​
​Call us for a quote or more information. 
317-849-5115 / 800-875-5196
Quick Quote
Picture
  • Steel components
  • Positive close
  • Non-standard bleed flow rates are available
  • Operating pressure: 3500 PSI
  • Temperature range: 250° f to -40° f
  • Reopening differential: 50 PSI
  • Closing flow tolerance: +15% / -0%

Vonberg 8800 Inline Flow Limiter Valve with 90-degree Swivel Elbow with Male SAE to Female SAE Ports​

In-line, 90° swivel elbow flow limiter. SAE o-ring outlet port. Prevents free fall during a line failure. Permits a controlled flow after closing of 2.0 - 3.0 gpm at 3500 PSI.
​Models:
  • 8804
  • 8806
  • 8808
  • 8810
  • 8812
  • 8816
​

​
Call us for a quote or more information. 
317-849-5115 / 800-875-5196
Quick Quote
Picture
  • Steel components
  • Positive close
  • Swivel design for easy alignment
  • 90° elbow for low profile applications
  • SAE o-ring port outlet for leak free connections
  • Non-standard bleed flow rates are available
  • Operating pressure: 3500 PSI
  • Temperature range: 250° f to -40° f
  • Reopening differential: 50 PSI
  • Closing flow tolerance: +15% / -0%

Vonberg 21800 Slip-in Cartridge Inline Velocity Fuse

In-line, slip-in cartridge velocity fuse. Provides full-line shut-off during a line failure. A flow below limit is permitted from port 1 to port 2. A flow above the limit is treated as a line failure and blocked.
​
​​Models:
  • 21800-006
  • 21800-008
  • 21800-010
  • 21800-012
  • 21800-014
  • 21800-016
  • 21800-024
​ Call us for a quote or more information. 
317-849-5115 / 800-875-5196
Quick Quote
Picture
  • Steel components
  • Operating pressure: 3500 PSI
  • Temperature range: 250° f to -40° f
  • Reopening differential: 50 PSI
  • Closing flow tolerance: +15% / -0%

Vonberg 28000-100 Inline Velocity Fuse with Female NPTF Ports

In-line velocity fuse. Female NPTF ports. Provides full-line shut-off during line failure. A flow below the limit is permitted from port 1 to port 2. A flow above the limit is treated as a line failure and blocked. Flow from port 2 to port 1 passes through the controlling orifice but is uncontrolled.

​Models:
  • 28000-102
  • 28000-103
  • 28000-104
  • 28000-106

​
​ ​ Call us for a quote or more information. 
317-849-5115 / 800-875-5196
Quick Quote
Picture
  • Steel components
  • Operating pressure: 3500 PSI
  • Temperature range: 250° f to -40° f
  • Reopening differential: 50 PSI
  • Closing flow tolerance: +15% / -0%

Vonberg 28000-200 Inline Velocity Fuse with Female SAE Ports

In-line velocity fuse. Female SAE ports. Full-line shut-off during a line failure. Flow below the limit is permitted from port 1 to port 2. Flow above the limit is treated as a line failure and blocked.
​
​​Models:
  • 28000-204
  • 28000-206
  • 28000-208
  • 28000-210
  • 28000-212


​ ​ Call us for a quote or more information. 
317-849-5115 / 800-875-5196
Quick Quote
Picture
  • Steel components
  • Operating pressure: 3500 PSI
  • Temperature range: 250° f to -40° f
  • Reopening differential: 50 PSI
  • Closing flow tolerance: +15% / -0%

Vonberg 28000-500 Inline Velocity Fuse with Male NPTF Connections​

In-line velocity fuse. Male NPTF connections. Full-line shut-off during a line failure. Flow below the limit is permitted from port 1 to port 2. Flow above the limit is treated as a line failure and blocked.
​Models:
  • 28000-502
  • 28000-503
  • 28000-504
  • 28000-506
  • 28000-508
  • 28000-512

​​Call us for a quote or more information. 
317-849-5115 / 800-875-5196
Quick Quote
Picture
  • Steel components
  • Operating pressure: 3500 PSI
  • Temperature range: 250° f to -40° f
  • Reopening differential: 50 PSI
  • Closing flow tolerance: +15% / -0%

Vonberg 28001-100 Inline Velocity Fuse with Female NPTF to Male JIC

In-line velocity fuse. Female NPTF inlet port and a male JIC outlet. Full-line shut-off during a line failure. A flow below limit is permitted from port 1 to port 2. Flow above limit is treated as a line failure and blocked.
Models:
  • 28001-102
  • 28001-103
  • 28001-104

​​Call us for a quote or more information. 
317-849-5115 / 800-875-5196
Quick Quote
Picture
  • Steel components
  • Fail safe design
  • Operating pressure: 3500 PSI
  • Temperature range: 250° f to -40° f
  • Reopening differential: 50 PSI
  • Closing flow tolerance: +15% / -0%

Vonberg 28001-200 Inline Velocity Fuse with Female SAE to Male JIC

In-line velocity fuse. Female SAE o-ring inlet and male JIC outlet. Full-line shut-off during a line failure. Flow below limit is permitted from port 1 to port 2. Flow above limit is treated as a line failure and blocked.

​Models:
  • 28001-204
  • 28001-206
  • 28001-208
  • 28001-210
  • 28001-212
​

Call us for a quote or more information. 
317-849-5115 / 800-875-5196
Quick Quote
Picture
  • Steel components
  • Fail safe design
  • Operating pressure: 3500 PSI
  • Temperature range: 250° f to -40° f
  • Reopening differential: 50 PSI
  • Closing flow tolerance: +15% / -0%

Vonberg 28001-500 Inline Velocity Fuse with Male NPTF to Male JIC

In-line velocity fuse. Male NPTF inlet and male JIC outlet. Full-line shut-off during a line failure. A flow below limit is permitted from port 1 to port 2. Flow above limit is treated as a line failure and blocked.
Models:
  • 28001-502
  • 28001-503
  • 28001-504
  • 28001-506
  • 28001-508
  • 28001-512​

Call us for a quote or more information. 
317-849-5115 / 800-875-5196
Quick Quote
Picture
  • Steel components
  • Fail safe design
  • Operating pressure: 3500 PSI
  • Temperature range: 250° f to -40° f
  • Reopening differential: 50 PSI
  • Closing flow tolerance: +15% / -0%

Vonberg 28001-800 Inline Velocity Fuse with Male SAE to Male JIC

In-line velocity fuse. Male SAE o-ring inlet and male JIC outlet. Full-line shut-off during a line failure. A flow below the limit is permitted from port 1 to port 2. Flow above the limit is treated as a line failure and blocked.
​Models:
  • 28001-804
  • 28001-806
  • 28001-808
  • 28001-810
  • 28001-812
  • 28001-816
  • 28001-824
​
Call us for a quote or more information. 
317-849-5115 / 800-875-5196
Quick Quote
Picture
  • Steel components
  • Operating pressure: 3500 PSI
  • Temperature range: 250° f to -40° f
  • Reopening differential: 50 PSI
  • Closing flow tolerance: +15% / -0%

Vonberg 28009-500 Inline Velocity Fuse with Male NPTF to Male ORS

In-line velocity fuse. Male NPTF inlet and male ORS outlet. Full-line shut-off during a line failure. A flow below the limit is permitted from port 1 to port 2. Flow above the limit is treated as a line failure and blocked.

​​Models:
  • 28009-502
  • 28009-503
  • 28009-504
  • 28009-506
  • 28009-508
  • 28009-512

Call us for a quote or more information. 
317-849-5115 / 800-875-5196
Quick Quote
Picture
  • Steel components
  • Fail safe design
  • Rapid response
  • Operating pressure: 3500 PSI
  • Temperature range: 250° f to -40° f
  • Reopening differential: 50 PSI
  • Closing flow tolerance: +15% / -0%

Vonberg 28009-800 Inline Velocity Fuse with Male SAE to Male ORS

In-line velocity fuse. Male SAE inlet and a male ORS outlet. Full-line shut-off during a line failure. Flow below limit is permitted from port 1 to port 2. Flow above is blocked.
​
Models:
  • 28009-806
  • 28009-808
  • 28009-810
  • 28009-812
  • 28009-816
  • 28009-824



Call us for a quote or more information. 
317-849-5115 / 800-875-5196
Quick Quote
Picture
  • Steel components
  • Operating pressure: 5000 PSI
  • Temperature range: 250° f to -40° f
  • Reopening differential: 50 PSI
  • Closing flow tolerance: +15% / -0%

Vonberg 28900-500 Inline Velocity Fuse with Male NPTF to Female NPTF

In-line velocity fuse. Male NPTF inlet and a female NPTF outlet. Full-line shut-off during line failure. Flow below limit passes from port 1 to port 2. Flow above limit is blocked.
​Models:
  • 28900-502
  • 28900-503
  • 28900-504
  • 28900-506
  • 28900-508

Call us for a quote or more information. 
317-849-5115 / 800-875-5196
Quick Quote
Picture
  • Steel components
  • Fail safe design
  • Rapid response
  • Operating pressure: 3500 PSI
  • Temperature range: 250° f to -40° f
  • Reopening differential: 50 PSI
  • Closing flow tolerance: +15% / -0%

Vonberg 28901-100 Inline Velocity Fuse with Female NPTF to Male NPTF

In-line velocity fuse. Female NPTF inlet and male NPTF outlet. Full-line shut-off during line failure. Flow below limit passes from port 1 to port 2. Flow above limit is blocked.
Models:
  • 28901-102
  • 28901-103
  • 28901-104
  • 28901-106

Call us for a quote or more information. 
317-849-5115 / 800-875-5196
Quick Quote
Picture
  • Steel components
  • Operating pressure: 3500 PSI
  • Temperature range: 250° f to -40° f
  • Reopening differential: 50 PSI
  • Closing flow tolerance: +15% / -0%

Vonberg 8100 Cartridge Velocity Fuse with Standard Cavity

Cartridge-style velocity fuse. Full-line shut-off during line failure. Flow below limit passes from port 1 to port 2. Flow above limit is blocked.
Models:
  • 8104
  • 8106
  • 8108
  • 8110
  • 8112
  • 8116

​
Call us for a quote or more information. 
317-849-5115 / 800-875-5196
Quick Quote
Picture
  • Steel components
  • Industry common cavity
  • Rapid response
  • Positive close
  • Operating pressure: 3500 PSI
  • Temperature range: 250° f to -40° f
  • Reopening differential: 50 PSI
  • Closing flow tolerance: +15% / -0%

Vonberg 8300 Inline Velocity Fuse with 90-degree Swivel Elbow and Male SAE to Female NPTF Ports

In-line velocity fuse. 90 degree swivel elbow. NPTF outlet port. Full-line shut-off during line failure. A flow below limit passes from port 1 to port 2. Flow above limit is blocked.
​
Models:
  • 8302
  • 8303
  • 8304
  • 8306


​
Call us for a quote or more information. 
317-849-5115 / 800-875-5196
Quick Quote
Picture
  • Steel components
  • Fail safe design
  • Rapid response
  • Positive close
  • Swivel design for easy alignment
  • 90° elbow for low profile applications
  • Operating pressure: 3500 PSI
  • Temperature range: 250° f to -40° f
  • Reopening differential: 50 PSI
  • Closing flow tolerance: +15% / -0%

Vonberg 8500 Inline Velocity Fuse - Threaded, Insertable

In-line, threaded, insertable velocity fuse. Full-line shut-off during line failure. Flow below limit passes from port 1 to port 2. Flow above limit is blocked. Flow from port 2 to port 1 passes through the controlling orifice but is uncontrolled.
Models:
  • 8504
  • 8506
  • 8508
  • 8510
  • 8512
  • 8516
  • 8520
  • 8524


Call us for a quote or more information. 
317-849-5115 / 800-875-5196
Quick Quote
Picture
  • Steel components
  • Rapid response
  • Positive close
  • Operating pressure: 3500 PSI
  • Temperature range: 250° f to -40° f
  • Reopening differential: 50 PSI
  • Closing flow tolerance: +15% / -0%

Vonberg 8700 Inline Velocity Fuse with 90-degree Swivel Elbow and Male SAE to Female SAE Ports

In-line velocity fuse. 90° swivel elbow. SAE o-ring outlet port. Full-line shut-off during line failure. A flow below limit passes from port 1 to port 2. Flow above limit is blocked.
Models:
  • 8704
  • 8706
  • 8708
  • 8710
  • 8712
  • 8716


​
Call us for a quote or more information. 
317-849-5115 / 800-875-5196
Quick Quote
Picture
  • Steel components
  • Fail safe design
  • Rapid response
  • Positive close
  • Swivel design for easy alignment
  • 90° elbow for low profile applications
  • SAE o-ring port outlet for leak free connections
  • Operating pressure: 3500 PSI
  • Temperature range: 250° f to -40° f
  • Reopening differential: 50 PSI
  • Closing flow tolerance: +15% / -0%
More from Vonberg Valve
Flow regulator valves
Directional valves
Hydraulic safety valves
Pressure Control Valves
​Valve bodies and manifolds
Indiana's certified fluid power specialists.
7751 E 89th St
Indianapolis, IN 46256
​
Local phone: 317-849-5115
Toll-free phone: 800-875-5196
Fax: 317-849-5255


Home
Parts Vendors
Hydraulic System Design
Hydraulic Repair
About Us
Contact

    Sign up for our free newsletter

Subscribe to Newsletter
Picture
© 2023 Progressive Power & Control
Indiana's Premiere Hydraulics Distributor
Site powered by Millaviant
  • Hydraulic Parts & Repair
    • Hydraulics Parts Vendors
    • Hydraulic Parts Repair and Remanufactured Parts
    • Emergency Hydraulic Repair & Replacement
  • Systems
    • JIE Drive
    • Mobile Hydraulics
    • Hydraulic Power Units >
      • Poclain Hydraulic Power Units
      • Nachi Hydraulic Power Units >
        • Nachi Servo Power Units
      • Yuken Hydraulic Power Units
    • Custom Hydraulic Systems and design
  • About PPC
    • Contact
    • Training
    • Terms and Conditions
  • Quick Quote
  • JIE Helical Gearmotor